1099-SSV (Copy) Test

View PDF

Single gang electrical box for use with nonmetallic sheathed cable

1099-SSV (Copy) Test

Single gang electrical box with air-seal flange, steel stud screws for use with non-load bearing studs 22 gauge or lighter

  • Carton Quantity: 48
  • Mounting Description: Steel stud screws for use with non-load bearing studs 22 gauge or lighter
  • Box Type: Wall - Switch/Receptacle
  • Box Features: Air-sealed flange (energy efficient), Screws
  • Installation Type: New Work
  • Height: 3-27/32 in
  • Width: 2-1/4 in
  • Depth: 3-9/16 in
  • Volume: 22.5 cu. in.
  • Number of Gangs: 1

Product Info

  • Brand: Vapor Seal
  • Carton Weight: 21 lbs 9.525 kg
  • Country of Origin: United States of America
  • Color: Off white
  • Patents: U.S. Patent No. 6,908,003 B2
  • Material: Fiberglass reinforced polyester
  • Additional Materials: Carbon steel fasteners, Polyurethane flange
  • Features:

    Polyurethane flange for single drywall offset, machine tapped device holes, leveling ribs, rigid hard box construction, no distortion with high temperatures, shatter resistant with low temperatures

  • Application:

    New work residential construction 2 HR fire resistive walls & ceilings – air-sealed electrical boxes for envelope walls and ceilings in Energy Star homes

  • Standards:

    ANSI / UL 514C: File No E30594

     

    https://ci3.googleusercontent.com/meips/ADKq_NaoGCyVrE4i64P90AIkBLp-iokVHdnQ9RSKsOnppPdLyxCunYYlJcjqxe93NdMcOPlKgJf-Pb3BXZpgHQsk7E-zvm-bGhAV8QavdRJk9rHA6T3iRodf9aoqUg=s0-d-e1-ft#https://www.alliedmoulded.com/wp-content/uploads/UL-Logo-250x332.jpg

  • Fire Classification:

    Fire Test of Building Construction Materials

    • ANSI / UL 263: File No. CEYY.R9379
      Note: Products must also be certified to: ANSI / UL 514C
      Fire Resistance Classification in Wall Assemblies 2-Hours or less
      For use in fire resistance walls constructed of min. 5-1/2 in. deep wood or nonbearing steel studs and gypsum wallboard and gypsum board with Classification periods of 2 hrs or less. Clearance between boxes and cutouts in wall shall not exceed 1/8 in. The area of openings for boxes shall not aggregate more than 100 sq in. per 100 sq ft of wall or partition area with no opening exceeding 35.2 sq in. Outlet boxes on opposite sides of wall or partition may be installed back-to-back.
      Fire Resistance Classification in Floor-Ceiling Assemblies 2-Hours or Less
      Distance between boxes in adjacent cavities may be reduced to 5 ½ inches
      Note: For more details please refer to the UL fire resistive directory and Allied Moulded’s CEYY.9379

Description

Single gang electrical box for use with nonmetallic sheathed cable

Additional information

Weight 21 lbs
Dimensions 20 × 16 × 10 in