4″ dia. round fan support box for use with nonmetallic sheathed cable
1/2″ deep base with side cube wiring capacity, fan/fixture screws for joist mounting
New and old work residential construction 2 HR fire resistive walls and ceilings (70 lbs. fan support and 110 lbs. fixture support)
ANSI / UL 514C: File No. E30594
Fire Test of Building Construction Materials
ANSI / UL 263: File No. CEYY.R9379 (Category / File No.)
Note: Products must also be certified to: ANSI / UL 514C
Fire Resistance Classification in Wall Assemblies 2-Hours or less
Shall be separated by a horizontal distance of not less than 3 inches
Fire Resistance Classification in Floor-Ceiling Assemblies 2-Hours or Less
Distance between boxes in adjacent cavities may be reduced to 5 ½ inches
Note: For more details please refer to the UL fire resistive directory and Allied Moulded’s CEYY.9379 (Outlet boxes and fittings classified for fire resistance)
4″ dia. round fan support box for use with nonmetallic sheathed cable
Weight | 16 lbs |
---|---|
Dimensions | 21 × 9 × 14 in |