Description
Single gang electrical box for use with nonmetallic sheathed cable
Thermoplastic Polyester Elastomer (TPE) flange for single drywall offset, Molded-in splined device holes
New work residential construction 2 HR fire resistive walls |
ANSI / UL 514C: File No. E30594
Fire Test of Building Construction Materials
ANSI / UL 263: File No. CEYY.R9379 (Category / File No.)
Note: Products must also be certified to: ANSI / UL 514C
Fire Resistance Classification in Floor-Ceiling Assemblies 2-Hours or Less
Distance between boxes in adjacent cavities may be reduced to 5 ½ inches
Note: For more details please refer to the UL fire resistive directory and Allied Moulded’s CEYY.9379 (Outlet boxes and fittings classified for fire resistance)
Single gang electrical box for use with nonmetallic sheathed cable
Our website uses cookies. By agreeing, you accept the use of cookies in accordance with our cookie policy. Continued use of our website automatically accepts our terms. Privacy Center